The cross bar is a 6, 8 or 6 twisted bar. This resulted in a higher load-bearing capacity of the grid with a lower self-weight.
According to the request of the grid customer, we deliver:
We do finishing tape by request. In this case, the length of the finishing tape is included in the final grating length.
Characteristic data of ALPO floor gratings are presented in the tables.
Type: PA PB PC
Performance | t [mm] | k [mm] |
---|---|---|
AND | 50 | 33 |
PB | 75 | 33 |
PC | 37,5 | 33 |
CAPACITY OF GRATINGS FOR CONCENTRATED LOAD
Ordinal number | Bearing lamella
h*b[mm] |
Flange
fi mm |
Mass (kg/m 2 ) | Support distance T [mm] | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
400 | 500 | 600 | 700 | 800 | 900 | 1000 | 1200 | 1400 | |||||||
AND | PB | PC | Allowed conc. load Q[kn] on a surface of 200*200mm | ||||||||||||
Priority.
smoke. |
20 | 25*2 | 6 | 16,6 | 15,2 | 18,1 | 2,1 | 1,6 | 1,3 | 1,1 | 0,9 | ||||
21 | 25*3 | 6 | 22,7 | 21,3 | 24,2 | 3,2 | 2,4 | 1,9 | 1,6 | 1,4 | 1,2 | 1,1 | 0,9 | ||
22 | 30*2 | 6 | 19,0 | 17,5 | 20,5 | 3,1 | 2,3 | 1,9 | 1,6 | 1,4 | 1,2 | 1,1 | 0,9 | ||
23 | 30*3 | 6 | 26,3 | 24,8 | 27,8 | 4,7 | 3,5 | 2,8 | 2,4 | 2 | 1,8 | 1,6 | 1,3 | 1,1 | |
24 | 40*2 | 6 | 23,9 | 22,4 | 25,4 | 6,1 | 4,5 | 3,6 | 3 | 2,6 | 2,3 | 2 | 1,7 | 1,4 | |
25 | 40*3 | 6 | 33,6 | 32,1 | 35,1 | 9,1 | 6,9 | 5,5 | 4,6 | 3,9 | 3,4 | 3 | 2,5 | 2,1 | |
Special
smoke. |
26 | 25*2,5 | 6 | 19,6 | 18,2 | 21,1 | 2,6 | 2 | 1,6 | 1,3 | 1,1 | 1 | 0,9 | ||
27 | 30*2,5 | 6 | 22,8 | 21,3 | 24,3 | 3,9 | 2,9 | 2,3 | 2 | 1,7 | 1,5 | 1,3 | 1,1 | 0,9 | |
28 | 40*2,5 | 6 | 28,8 | 27,3 | 30,3 | 7,6 | 5,7 | 4,5 | 3,8 | 3,2 | 2,8 | 2,5 | 2,1 | 1,7 | |
29 | 50*3 | 8 | 44,5 | 41,9 | 47,2 | 14 | 10,5 | 8,4 | 7 | 6 | 5,2 | 4,7 | 3,8 | 3,2 | |
30 | 50*4 | 8 | 56,6 | 54,0 | 59,3 | 18,7 | 14 | 11,2 | 9,3 | 8 | 7 | 6,2 | 5,1 | 4,3 | |
31 | 60*4 | 8 | 66,4 | 63,7 | 70,0 | 28,1 | 21,1 | 16,9 | 14 | 12 | 10,5 | 9,4 | 7,7 | 6,5 | |
32 | 60*5 | 8 | 81,1 | 78,4 | 83,8 | 35,2 | 26,4 | 21,1 | 17,6 | 15,1 | 13,2 | 11,7 | 9,6 | 8,1 |
CAPACITY OF GRATINGS FOR CONTINUOUS LOADING
Ordinal number | Bearing lamella
h*b[mm] |
Add. mine. bending
[kN m/m] |
Support distance T [mm] | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
500 | 600 | 700 | 800 | 900 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | |||
Permitted continuous load q [kN/m 2 ] | |||||||||||||||
20 | 25*2 | 0,644 | 20,6 | 14,3 | 10,5 | 8,0 | 6,4 | 5,1 | 3,6 | 2,6 | 2,0 | ||||
21 | 25*3 | 0,966 | 30,9 | 21,5 | 15,8 | 12,1 | 9,5 | 7,7 | 5,4 | 3,9 | 3,0 | ||||
22 | 30*2 | 0,938 | 30,0 | 20,8 | 15,3 | 11,7 | 9,3 | 7,5 | 5,2 | 3,8 | 2,9 | 2,3 | |||
23 | 30*3 | 1,414 | 45,2 | 31,4 | 23,1 | 17,7 | 14,0 | 11,3 | 7,8 | 5,8 | 4,4 | 3,5 | |||
24 | 40*2 | 1,82 | 58,2 | 40,4 | 29,7 | 22,7 | 18,0 | 14,6 | 10,1 | 7,4 | 5,7 | 4,5 | 3,6 | 3,0 | 2,5 |
25 | 40*3 | 2,744 | 87,8 | 61,0 | 44,8 | 34,3 | 27,1 | 22,0 | 15,2 | 11,2 | 8,6 | 6,8 | 5,5 | 4,5 | 3,8 |
26 | 25*2,5 | 0,793 | 25,5 | 17,7 | 13,0 | 10,0 | 7,9 | 6,4 | 4,4 | 3,2 | 2,5 | ||||
27 | 30*2,5 | 1,176 | 37,6 | 26,1 | 19,2 | 14,7 | 11,6 | 9,4 | 6,5 | 4,8 | 3,7 | 2,9 | |||
28 | 40*2,5 | 2,268 | 72,6 | 50,4 | 37,0 | 28,3 | 22,4 | 18,1 | 12,6 | 9,2 | 7,1 | 5,6 | 4,5 | 3,7 | 3,1 |
29 | 50*3 | 4,2 | 134,4 | 93,3 | 68,6 | 52,5 | 41,5 | 33,6 | 23,3 | 17,1 | 13,1 | 10,4 | 8,4 | 6,9 | 5,8 |
30 | 50*4 | 5,6 | 179,2 | 124,4 | 91,4 | 70,0 | 55,3 | 44,8 | 31,1 | 22,8 | 17,5 | 13,8 | 11,2 | 9,2 | 7,8 |
31 | 60*4 | 8,44 | 270,1 | 187,6 | 137,8 | 105,5 | 83,4 | 67,5 | 46,9 | 34,4 | 26,4 | 20,8 | 16,9 | 13,9 | 11,7 |
32 | 60*5 | 10,56 | 337,8 | 234,6 | 172,3 | 132,0 | 104,3 | 84,5 | 58,7 | 43,1 | 33,0 | 26,1 | 21,1 | 17,4 | 14,7 |
(The mass of the grids is specified for the version without the final strip and without surface protection)
Allowed continuous opt. qi concentrated opt. Q is specified with an allowable stress of 140 N/mm 2